EasyManua.ls Logo

GE P54E - Page 810

GE P54E
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B - Settings and Signals
P54A/B/C/E
B244
P54xMED-TM-EN-1
ORDINAL SIGNAL NAME ELEMENT NAME
DESCRIPTION
699
Pole Discrepancy
DDB_POLE_DISCREPENCE_TRIP
Pole Discrepancy (signal raised when a pole discrepancy state is detected on CB)
700
VN>1 Trip
DDB_RESOV_1_TRIP
Residual overvoltage stage 1 trip
701
VN>2 Trip
DDB_RESOV_2_TRIP
Residual overvoltage stage 2 trip
702
Fault REC TRIG
DDB_FAULT_RECORDER_START
Trigger for Fault Recorder
736
Any Start
DDB_ANY_START
Any Start
737
IDiff>Start
DDB_DIFFERENTIAL_START
Current differential start
738
IDiff>Start A
DDB_DIFFERENTIAL_START_A
Current differential A phase start
739
IDiff>Start B
DDB_DIFFERENTIAL_START_B
Current differential B phase start
740
IDiff>Start C
DDB_DIFFERENTIAL_START_C
Current differential C phase start
761
I>1 Start
DDB_POC_1_3PH_START
1st stage overcurrent start 3 phase
762
I>1 Start A
DDB_POC_1_PH_A_START
1st stage overcurrent start phase A
763
I>1 Start B
DDB_POC_1_PH_B_START
1st stage overcurrent start phase B
764
I>1 Start C
DDB_POC_1_PH_C_START
1st stage overcurrent start phase C
765
I>2 Start
DDB_POC_2_3PH_START
2nd stage overcurrent start 3 phase
766
I>2 Start A
DDB_POC_2_PH_A_START
2nd stage overcurrent start phase A
767
I>2 Start B
DDB_POC_2_PH_B_START
2nd stage overcurrent start phase B
768
I>2 Start C
DDB_POC_2_PH_C_START
2nd stage overcurrent start phase C
769
I>3 Start
DDB_POC_3_3PH_START
3rd stage overcurrent start 3 phase
770
I>3 Start A
DDB_POC_3_PH_A_START
3rd stage overcurrent start phase A
771
I>3 Start B
DDB_POC_3_PH_B_START
3rd stage overcurrent start phase B
772
I>3 Start C
DDB_POC_3_PH_C_START
3rd stage overcurrent start phase C
773
I>4 Start
DDB_POC_4_3PH_START
4th stage overcurrent start 3 phase
774
I>4 Start A
DDB_POC_4_PH_A_START
4th stage overcurrent start phase A
775
I>4 Start B
DDB_POC_4_PH_B_START
4th stage overcurrent start phase B
776
I>4 Start C
DDB_POC_4_PH_C_START
4th Stage overcurrent start phase C
777
IN>1 Start
DDB_EF1_1_START
1st stage stand by earth fault (SBEF) overcurrent start
778
IN>2 Start
DDB_EF1_2_START
2nd stage stand by earth fault (SBEF) overcurrent start
779
IN>3 Start
DDB_EF1_3_START
3rd stage stand by earth fault (SBEF) overcurrent start
780
IN>4 Start
DDB_EF1_4_START
4th stage stand by earth fault (SBEF) overcurrent start

Table of Contents