7
FRUReplacement
FRUReplacementProcedures
RequiredToolsandSupplies
TomaintainandrepairtheT2100Treadmill,youwillneedthefollowing:
•Standardhandtools,including:
•SocketandDriverset–9mm(3/8”)or12mm(1/2”)drive,includingextensions
and9mm(3/8”),11mm(7/16”),12mm(1/2”),14mm(9/16”)sockets
•Wrenchset–withopposite"box"and"open"endsin9mm(3/8”),11mm(7/16”),
12mm(1/2”),14mm(9/16”)
•Screwdrivers–smallandmediumsize"at"tipand"Phillips"tip
•Needlenosepliers
•CrescentWrench/ChannelLocks–40mm(11/2”)minimum
•HexKeyset–3mm(1/8”),4mm(5/32”),6mm(1/4”)
•Carpenter’slevel
•DigitalVoltageOhmMeter(DVOM)
•LeakagecurrenttesterPNMT-1216-01(for120V),PNMT-1216-02(for240V),or
equivalent
•CASETreadmillInterfacecablePN700609-002
•Antisepticcleaner
•Dustremover(compressedair)
TreadmillShutdown
ThisprocedureshallbeperformedpriortoreplacinganyTreadmillFRUs.
•Stopthetreadmillbyusingthecontrollingdeviceoremergencystopswitchwhen
appropriate.
•PlacetheON/OFFswitchtotheOFF(O)position.
•DisconnectfromsupplymainsbyunpluggingpowercordfromwallandT2100.
2021403-120F
T2100Treadmill
105