ProcessorBoardStatusLEDs
Removetheshroudande-boxcovertoviewtheprocessorboardstatusLEDs.
•Whenpowerisappliedtothee-box,theLEDswillturnonveryquicklyinsequence,
startingatDS6andgoingtoDS1.
•Ifself-calibrationhasneverbeenperformed,theLEDswillstayonuntilthe
self-calibrationroutineisperformed.
•Ifself-calibrationhasbeenperformed,theLEDswillallturnoffandthenbehaveas
describedinthetablebelow.
•Whenpowerisremovedfromthee-box,allLEDswillturnonuntilthesystemhas
completedtheshutdownroutines.
ArrowpointstoStatusLEDs
LEDStatusName
Description
DS1
Elevation/Calibration
ThisLEDtogglesonoroffevery500msifan
elevationerrorhasoccurred.Whentheelevation
erroriscleared,theLEDisoff.Duringcalibration
thisLEDwillturnon,andwhenalimitswitchis
reachedtheLEDwillashrapidlyfor100ms.
DS2
Drive/Burn-In
ThisLEDtogglesonoroffevery500msifadrive
errorhasoccurred.Whenthedriveerroris
cleared,theLEDisoff.Also,theLEDwillturnon
whenburn-inisactivated.Duringtheburn-in
cycle,theLEDwillashrapidlyfor100msevery
timethebeltspeedincreases.