EasyManua.ls Logo

GEA D 10 - Temperature & Ejection Alarm Settings

GEA D 10
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
2.2 Alarm settings for temperature and ejection monitoring
Separator model
OSD
HFO
98 °C
105 °C
90 °C
OSD 60
5 A
RPM
LO
95 °C
105 °C
85 °C
OSD 35
3 A
RPM
MDO
40 °C
50 °C
30 °C
OSD 18
0,5 A
RPM
DO
20 °C
30 °C
10 °C
OSD 6
0,5 A
RPM
Remarks
Separating temperature
Settings dependent
on state of the energy
supply and the clutch
shoes.
Settings dependent
on state of the energy
supply and the clutch
shoes.
Control
Text d is pla y
TAH product feed
Temp. >max
Separation “Stop”
Alarm #06 Help
TAL product feed
Temp.< min
Separation “Stop”
Alarm #05 Help
Ejection monitor
Eject. Curr.< offset
Separation “Stop”
Alarm #07 Help
Ejection monitor
Eject. Speed< offset
Separation “Stop”
Alarm #33 Help
Complete text
Temp. alarm high
Alarm is triggered when
the pre-set temperature
is exceeded.
Temp. alarm low
Alarm is triggered when
the pre-set temperature
is undershot.
Alarm for monitoring the
ejection after end of se-
parating time or after
SMS ejection.
The motor current is
monitored.
Alarm for monitoring the
ejection after end of se-
parating time or after
SMS ejection.
The bowl speed is moni-
tored.
Alarms
Temperature monitoring
TAH product feed
Temp. >max
TAL product feed
Temp.< min
Ejection monitoring
Eject. Curr.< offset
Eject. Speed< offset
(option)

Related product manuals