Mechanical Separation / GEA Westfalia Separator
4.25 Alarm #38 - Min. speed monitoring (option)
MIN. SPEED
MONITORING
during operation
Alarm#38 ENTER
Text display Possible causes Action
Actual speed lower than the permitted
speed.
Check speed.
Speed setting for minimum speed too
high.
Check maximum speed setting.
Frequency not stable.
Check frequency.
Drive (50 or 60 Hz) of separator does
not match frequency on site.
Check separator configuration for
the frequency with the frequency on
site.
Speed pickup defective.
Check speed pickup electrically;
replace if necessary.
Deselect function if required.
Note :
Alarm #38 only active when speed pickup is installed!
Help text information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
MIN. SPEED
MONITORING
Please check:
Operating speed
->
Page 2
Min. speed
Setting
Frequency
Sep. configuration
->
Page 3
Frequency
Frequency on site
Speed pickup
back with ENTER
F1