4.25 Alarm #38 - Min. speed monitoring (option)
MONITORING
during operation
Text display Possible causes Action
Actual speed lower than the permitted
speed.
• Check speed.
Speed setting for minimum speed too
high.
• Check maximum speed setting.
Frequency not stable.
•
Drive (50 or 60 Hz) of separator does
not match frequency on site.
• Check separator configuration for
the frequency with the frequency on
site.
• Check speed pickup electrically;
•
Deselect function if required.
Note :
Alarm #38 only active when speed pickup is installed!
Help text – information on the control system
Step 1 Acknowledge fault
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
MIN. SPEED
MONITORING
Please check:
Operating speed
Page 2
Min. speed
Setting
Frequency
Sep. configuration
Page 3
Frequency
Frequency on site
Speed pickup
back with ENTER