66 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
4.21 Alarm #34 - Bowl monitoring (option)
BOWL MONITORING
Speed too high
during TIMER 06
Alarm#34 ENTER
Text display Possible causes Action
Closing water pulse T06 too long,
bowl has opened.
• Check T06.
Water pressure for hydraulics during
T06 too high, bowl has opened.
• Check water pressure with open
valve V3.
Valve V3 is soiled, catches, remains
open too long.
• Check valve V3.
New clutch shoes fitted.
•
Check speed offset.
New drive belt fitted.
•
Check drive belt.
•
Deselect function if required.
Note :
Alarm #34 only active when speed pickup is installed!
Help text – information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
BOWL MONITORING
Please check:
Timer 06
Water pressure hydr.
->
Page 2
Function V3
Speed< offset
Bowl monitoring
->
Page 3
back with ENTER
F1