4.30 Alarm #43 - PT2 sensor active when idling
WHEN IDLING
Text display Possible causes Action
Pressure transmitter PT2 was acti-
vated when idling.
• Check pressure transmitter PT2.
Filling water valve V2 leaks.
•
Product valve V1 doesn’t close prop-
erly.
• Check valve V1.
Non-return flap at V7 jams,
product runs back into the bowl.
• Close clean oil discharge valve
(product discharge valve) V7 when
idling.