8555-9201-000 / 0109 9
Mechanical Separation / GEA Westfalia Separator
1.2 Timer list OSD 18-...-…
Timer
Control D10
Remarks
Separator model
Complete text Display text
OSD 18
-0136-
-0196-
-91-
HFO
LO
LO / (M)DO / HFO
secs
T00
Partial ejection
Partial ejection
2 2 2
T01
Displacement
Displacement
13 13 13
T02
Filling
Filling
13 13 13
T03
Waiting
Waiting
5 5 5
T04
Total ejection
Total ejection
2.5 2.5 2.5
T05
Speed recovery after total ejection
Speed recov. total
10 10 10
T06
Closing water impulse
Closingwater imp
0.1 0.1 0.1
T07
Alarm delay
Alarm delay
10 10 10
T08
Waiting after displacement
Wait aft.displac
5 5 5
T09
Waiting after filling
Wait aft.filling
5 5 5
T10
Separator starting
Sep. runup
240 240 240
T11
Alarm bridging
Alarm-bridging
30 30 30
T12
Waiting after 1st ejection
Wait aft 1. Eject
5 5 5
T13
Speed recovery after partial ejection
Speed rec.part Speed
10 10 10
T14
Closing water interval
Closing Interval
600 600 600
T15
Circulation valve close
Circ.valve clos
60 0 0
T16
Circulation valve open
Circ.valve open
5 0 0
T17
Water content bridging
Water cont. bridging
0 600 0
T18
Sludge tank alarm delay
LSHH-Sludgetank
10 10 10
T19
Water impulse at start
Water pulse bef. start
3 3 3
T20
Separation
Separation
no password
7 200 7 200 7 200
T21
Min. separation time
Min-Sep.-Time
600 0 0
T22
High water content
High water cont.
15 15 0
T23
Feed pump delay
Feed pump delay
300 300 300
T24
Sludge pump delay off
Sludgep.delay
60 60 60
T25
Vibration 1 - delay
Vibro 1
option
180 180 180
T26
Vibration 2 -delay
Vibro 2
option
2 2 2
T27
SMS low pressure delay
SMS PSL delay
10 0 0
T28
Ejection monitoring
Ejection monitor
5 5 5
T29
Brake for separator
Brake for Sep.
option
600 600 600
T30
Free
Free
T31
Free
Free
T32
WMS-Mode
WMS-Mode
0 5 400 0
T33
SMS-Mode
SMS-Mode
0 120 0
T34
Circuit valve delay
Circuirt v. delay
0 10 0
T35
Water seal broken
Water.Seal
0 10 0
T36
SMS Press.Check
SMS Press.Check
0 1 0
T37
SMS Waiting
SMS Waiting
0 3 0
T38
WMS sensor flushing
WMS sens. flushing
0 20 0
T39
Separator motor off
Separator off
1 800 1 800 1 800
T40
CU sludge pump on
CE sludgepump on
option
60 60 60
T41
CU sludge pump delay
CU-Sl.Pu delay
option
600 600 600
T42
Free
Free
- - -
T43
Free
Free
- - -
T44
SMS sensor check
SMS sensor check
option
60 60 0
T45
WMS sensor check
WMS sensor check
option
300 20 0
T46
Free
Free
- - -
T47
Min.SMS Time
Min. SMS Time
0 7 0
T60
Start impulse
Start impulse
option
20 20 0
T61
Sensor interval
Sensor interval
option
2 2 0
T62
Sensor impulse
Sensor impulse
option
1 1 0