Mechanical Separation / GEA Westfalia Separator
4.22 Alarm #35 - Separator start monitoring (option)
SEPARATOR START
Monitoring
during T10
Alarm#35 ENTER
Text display Possible causes Action
Separator starting time T10 too short.
Check T10.
Brake not released.
Check brake.
Clutch shoes worn or oily.
Check clutch shoes.
Drive belt worn or oily.
Check drive belt; replace if neces-
sary.
Speed setting for minimum operating
speed too high.
Check speed setting.
Speed pickup defective.
Check speed pickup electrically;
replace if necessary.
Deselect function if required.
Note :
Alarm #35 only active when speed pickup is installed!
Help text information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
SEPARATOR START
Please check:
Timer 10 too short
Release brake
->
Page 2
Clutch shoes oily
Belt oily
Setting
Speed min.
->
Page 3
Speed pickup
defective
back with ENTER
F1