4.34 Alarm #48 - Water discharge
WATER DISCHARGE:
Overflow
Separation “Stop”
Alarm#48 Act. ENTER
Text display Possible causes Action
Water content in product feed too
high.
• Check product feed.
Clean oil discharge pressure (product
discharge pressure) too high.
• Check clean oil discharge valve
(product discharge valve) V7.
Filling water volume too small.
• Check function V2 and filling water
volume.
Product temperature too low.
•
Check product temperature.
Regulating ring too large.
•
Fit next smaller regulating ring.
Water pressure for hydraulics too high
or closing water pulse T06 too long.
• Check water pressure with open
valve and
•
check T06.
Polyamide gasket in bowl top defec-
tive.
• Check polyamide gasket in bowl
top.
Gaskets in bowl defective.
•
Check gaskets.
Pressure switch PT2 defective.
•
Check pressure switch PT2.
Help text – information on the control
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
WATER DISCH. - OVERFLOW
Please check:
Clean oil disharge valve V7
Function V2
->
Page 2
Water content in feed
Fillling water volume
Product temperature
Regulating ring
->
Page 3
Polyamide gasket
Pressure switch PT2
back with ENTER