8555-9201-000 / 0109 79
Mechanical Separation / GEA Westfalia Separator
4.34 Alarm #48 - Water discharge
WATER DISCHARGE:
Overflow
Separation “Stop”
Alarm#48 Act. ENTER
Text display Possible causes Action
Water content in product feed too
high.
Check product feed.
Clean oil discharge pressure (product
discharge pressure) too high.
Check clean oil discharge valve
(product discharge valve) V7.
Filling water volume too small.
Check function V2 and filling water
volume.
Product temperature too low.
Check product temperature.
Regulating ring too large.
Fit next smaller regulating ring.
Water pressure for hydraulics too high
or closing water pulse T06 too long.
Check water pressure with open
valve and
check T06.
Polyamide gasket in bowl top defec-
tive.
Check polyamide gasket in bowl
top.
Gaskets in bowl defective.
Check gaskets.
Pressure switch PT2 defective.
Check pressure switch PT2.
Help text information on the control
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
WATER DISCH. - OVERFLOW
Please check:
Clean oil disharge valve V7
Function V2
->
Page 2
Water content in feed
Fillling water volume
Product temperature
Regulating ring
->
Page 3
Polyamide gasket
Pressure switch PT2
back with ENTER