On a spring-closing valve there is danger of injury when the clamp connection
(43.1) is opened, as the released spring pretension will suddenly lift the
actuator. Therefore, release the spring tension before detaching the clamp
connection (46) by supplying the actuator (A) with compressed air.
Before starting any maintenance, servicing or repair work, disconnect the
valve from the power supply and secure it against inadvertently being
switched back on again.
Only allow a qualified electrician to carry out any work on the electrical power
supply.
Check the electrical equipment of the valve at regular intervals. Immediately
remedy loose connections and molten cables.
If work on live parts cannot be avoided, call in a second person, who can
operate the main switch in case of an emergency.
The housing sockets (402) have very sharp edges. When transporting and
installing the valve be sure to wear suitable protective gloves.
When the valve switches, when the valve seat is being cleaned or if a seal is
defective, cleaning medium exits from the leakage outlet (15) of the rinsing
valve. Collect this liquid in a suitable container such as a funnel or a drip pan
and discharge it in a safe manner. Observe the instructions in the safety data
sheets issued by the cleaning agent manufacturers.
Safety
430BAL008386EN_3
07.02.2022 17