RS5/6-34 Telescopic Handler HYDRAULICS
CONTROL AND PARK BRAKE PILOT PRESSURE TROUBLESHOOTING
Test the pressure at the solenoid inputs of the main control
valve. Does the pressure gauge read 350 psi (24 bar)?
Repair or replace the control solenoid
or control spool affected.
Test the pressure at the JP port of the flow
. divider. Does the pressure gauge read
YES
NO
YES
NO
NO
YES
YES
NO
YES
NO
350 psi (24 bar)?
Repair or replace the joystick control.
Test the pressure of the PB port of the flow
divider. Does the pressure gauge read
350 psi (24 bar)?
Apply the park brake. Does the pressure
gauge read 350 psi (24 bar)?
Replace the flow divider. Does the pressure
gauge at port P1 of the SAHR valve read
350 psi (24 bar)?
Repair the park brake
cylinders.
Replace the flow
divider.
Remove the pressure gauge.
Replace the pump.
View thousands of Crane Specifications on FreeCraneSpecs.com
View thousands of Crane Specifications on FreeCraneSpecs.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gehl RS5-34 and is the answer not in the manual?

Gehl RS5-34 Specifications

General IconGeneral
BrandGehl
ModelRS5-34
CategoryConstruction Equipment
LanguageEnglish

Related product manuals