25. Procedures for Maintenance
3-34
8) After flushing with running water, stop the engine, drain
the cooling system completely and then install the drain
plug (P).
9) Pour water mixed with anti-freeze into the water supply
port of the radiator, to fill it up.
10) To bleed air, idle the engine for 5 to 6 minutes and then
run the engine without load at high speed for 5 to 6
minutes. (While running the engine, keep the radiator
cap (2) removed.)
11) Approximately 5 minutes after stopping the engine,
pour water mixed with anti-freeze up to the water sup-
ply port of the radiator, and install and tighten the cap.
12) Drain the cooling water from the sub-tank (3), wash
the inside of the sub-tank (3) and pour water mixed
with anti-freeze up to the "FULL" level.
LOW
FULL
(3)
020290-00X