25. Procedures for Maintenance
3-53
How to release air:
This machine is equipped with an automatic air release de-
vice (a solenoid pump). Follow the air release procedure
below:
1) Fill up the fuel tank.
2) Set the lock levers to the lock position and the acceler-
ator lever to the "RUN" position.
3) Turn the starter switch to the "ON" position and leave it
for approximately 10 to 15 seconds. (The air will nor-
mally be released in 10 to 15 seconds.)
4) Turn the starter switch to the "START" position and start
the engine.
IMPORTANT
If the engine fails to start, turn the starter switch back
to the "OFF" position and wait at least one minute be-
fore again turning the starter switch to the "START"
position.
Whenever you refuel, release air from the fuel tank in the
same way.
If the engine revolves irregularly after it starts, turn the
starter switch to the "OFF" position, wait one minute or
more and turn the starter switch to the "START" position
again.