21
ENGLISH
14.1.3.10 Amount of regenerations carried out
Display shows:
Press P to confirm.
14.1.3.11 Amount of treated water
Display shows:
Press P to confirm.
14.1.3.12 Model
Display shows:
DO NOT CHANGE THIS VALUE, press P button to confirm.
14.1.3.13 Saving
Display shows:
Press C button to change the value; press P to save or not.
14.1.4 Set regeneration mode
Display shows:
Regeneration can take place in three different operating modes:
- Mode 1: Regeneration takes place by time, it means every “n” set days
and at the time set.
- Mode 2: Regeneration takes place as soon as softening capacity is
exhausted, regardless of the days passed and respecting the
time set in the PROGRAMMING FOR THE END USER (see
section 14.2).
- Mode 3: Regeneration takes place as soon as softening capacity is
exhausted. Days and time shall not be set.
Press C button to change regeneration mode.
Press P button to confirm.
- If you choose “Mode 1”:
Display will show:
This is the regeneration frequency in days.
The cursor shows the number to be changed, so press C button to change
the first figure (values to be set are 0 or 1) and S button to move cursor
to the second figure.
Press P button to confirm the regeneration frequency.
P.S. The maximum regeneration frequency to be set is 12 days.
14.1.5 Set water hardness
Display shows:
Water hardness is expressed in milligrams per litre (1° f corresponds to
10 mg/l).
The cursor shows the number to be changed, so press C button to change
the first figure, that is the thousands, and S button to move cursor to the
other figures (hundreds, tens, units).
Example: If you have to set 45 °f (= 450 mg/l) you shall press S and C
buttons until you reach the value of 0450 mg/l:
Press P button to confirm the hardness.
14.1.6 Set iron level in water
Display shows:
Iron in water is expressed in milligrams per litre.
The cursor shows the number to be changed, so press C button to change
the first figure and S button to move cursor to the second figure.
P.S. If iron has decimal figures, please set the next unit value.
Example: If Iron is 1,2 mg/l, set 2 mg/l.
Press P button to confirm Iron value..
14.1.7 Set manganese in water
Display shows:
Manganese in water is expressed in milligrams per litre.
The cursor shows the number to be changed, so press C button to change
the first figure and S button to move cursor to the second figure.
P.S. If Manganese has decimal figures, please set the next unit value.
Example: If Manganese is 0,2 mg/l, set 1 mg/l.
Press P button to confirm Manganese value.
.
14.1.8 Set regenerant type
Display shows:
Press C button to change regenerant type:
Sodium chloride = Sodium (kitchen salt)
Potassium chloride = Potassium (to be use for irrigation only)
Press P button to confirm
14.1.9 Display Comp. Hardness
Display shows:
Compensated hardness is made up of the values of hardness, iron and
manganese set.
Press P button to confirm
H-Tot. Reg 00000
H-Tot. L 00000000
H-Model #M400
H-Save Yes
Mode 2
Regen Freq . 0 2
Hardness mg/L 0 6 8 5
Hardness mg/L 0 4 5 0
Iron mg/L 0 0
Mang. mg/L 0 0
Salt = Sodium
Comp. Hard 0 0 4 5 0