PART 2
AC GENERATORS
Page 46
Section 2.3
Troubleshooting Flow Charts
GOOD
REPAIR OR REPLACE
IF RECONFIGURED TO LP GAS,
VERIFY THAT PROPER
PROCEDURE WAS FOLLOWED
(REFER TO SECTION 1.3)
TEST 14 - CHECK
VOLTAGE AND
FREQUENCY
UNDER LOAD
TEST 15 - CHECK
FOR OVERLOAD
CONDITION
GO TO “PROBLEM 18 -
ENGINE STARTS HARD
AND RUNS
ROUGH/LACKS POWER”
SECTION 4.3
TEST 16 - CHECK
ENGINE CONDITION
NOT
OVERLOADED
GOOD
ENGINE
CONDITION
GOOD
DISCONTINUE
TESTING
LOOK FOR A SHORTED CONDITION
IN A CONNECTED LOAD OR IN ONE
OF THE LOAD CIRCUITS
REDUCE LOADS TO UNIT’S
RATED CAPACITY
BAD
REPAIR OR REPLACE
OVERLOADED
Problem 3 – Voltage and Frequency Drop Excessively When Loads Are Applied
TEST 7 - CHECK
STATOR AC
POWER WINDINGS
BOTH
LOW
GOOD
BAD
GOOD
TEST 12 - CHECK
STEPPER MOTOR
CONTROL
PROCEED TO PROBLEM 1
TEST 1 – CHECK
AC OUTPUT
VOLTAGE
ERRATIC
HIGH
OR
LOW
Problem 4 – Unstable Voltage or Incorrect Output Which is Not Triggering a Shutdown
TEST 3 -
CALIBRATE
VOLTAGE

Table of Contents

Other manuals for Generac Power Systems 13 kW NG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems 13 kW NG and is the answer not in the manual?

Generac Power Systems 13 kW NG Specifications

General IconGeneral
BrandGenerac Power Systems
Model13 kW NG
CategoryPortable Generator
LanguageEnglish

Related product manuals