Troubleshooting
38 Installation Guidelines for 60 Hz EcoGen™ Generator
Generator Troubleshooting
Table 8-2. Generator Troubleshooting
Active Alarm LED  Problem
Things to
Check 
Solution
NONE GREEN Unit running in 
AUTO but no 
power in house.
Check 
Generator 
Disconnect 
circuit breaker.
Contact Independent Authorized Servicing Dealer if 
Generator Disconnect circuit breaker is in the ON position.
HIGH 
TEMPERATURE
RED Unit shuts down 
during operation.
Check the 
LEDs/Screen for 
alarms.
Check ventilation around the intake, exhaust and rear of 
generator. Contact s Independent Authorized Servicing 
Dealer if no obstruction is found.
OVERLOAD 
REMOVE LOAD
RED Unit shuts down 
during operation.
Check the 
LEDs/Screen for 
alarms.
Clear alarm and remove household loads from the generator. 
Put back in AUTO and restart.
RPM SENSE 
LOSS
RED Unit was running 
and shuts down, 
attempts to 
restart.
Check the 
LEDs/Screen for 
alarms.
Clear alarm and remove household loads from the generator. 
Put back in AUTO and restart. If problem returns, contact 
Independent Authorized Servicing Dealer to investigate 
possible fuel issue.
NOT 
ACTIVATED
NONE Unit will not start 
in AUTO with 2-
wire start signal.
See if screen 
says unit not 
activated.
Refer to 
Activation.
None GREEN Unit will not start 
in AUTO with 2-
wire start signal.
Check screen 
for start delay 
countdown.
If the start up delay is greater than expected, contact 
Independent Authorized Servicing Dealer to adjust from 2 to 
1500 seconds.
LOW OIL 
PRESSURE
RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Check oil level. Add oil per Owner’s Manual. Contact 
Independent Authorized Servicing Dealer if oil level is 
correct.
RPM SENSE 
LOSS
RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Clear alarm. Navigate to the BATTERY MENU on the control 
pad LCD. Contact Independent Authorized Servicing Dealer 
if battery is GOOD. Replace battery If CHECK BATTERY is 
displayed.
OVERCRANK RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Check fuel line shutoff valve is in the ON position. Clear 
alarm. Attempt to start the unit in MANUAL. If it does not start 
or starts and runs rough, contact Independent Authorized 
Servicing Dealer.
LOW VOLTS 
REMOVE LOAD
RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Clear alarm and remove household loads from the generator. 
Set back to AUTO and restart.
FUSE PROBLEM RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Check ATO 7.5 Amp fuse. Replace with same type fuse if 
bad. Contact Independent Authorized Servicing Dealer if fuse 
is good.
OVERSPEED RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Contact Independent Authorized Servicing Dealer.
UNDER
VOLTAGE
RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Contact Independent Authorized Servicing Dealer.
UNDERSPEED RED Unit will not start 
in AUTO with 2-
wire start signal.
Check the 
LEDs/Screen for 
alarms.
Contact Independent Authorized Servicing Dealer.