Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
44
SLAVE ADDRESS (v 1.19.06 or later)
Path: / CONFIGS COMM-PARAM PORT-3 SLAVE-ADDRESS
Type: Data Editor
Syntax: SLAVE-ADDRESS [= n] | [D]
Range: Integer: 0 .. 31
Notes: SLAVE-ADDRESS is the address of this unit (a slave, controlled) on the multi-drop
RS-485 bus. There are a maximum on 32 addresses, ranging from 0 to 31. On the
bus, the actual ASCII value used for addressing is the address assigned here plus
the value of the parameter ADDRESS OFFSET.
SLOPE
Path: / CONFIGS OPERATION ANALOG-OUTPUTS DAC1 DAC1-SLOPE
Type: Data Editor
Syntax: DAC1-SLOPE [= n] | [D]
Range: Real: -1.000 .. 1.000 (volts/dB)
Notes: SLOPE controls the rate of change of the DC output voltage with respect to a 1 dB
change in signal power level.
SLOPE
Path: / CONFIGS OPERATION ANALOG-OUTPUTS DAC2 DAC2-SLOPE
Type: Data Editor
Syntax: DAC2-SLOPE [= n] | [D]
Range: Real: -1.000 .. 1.000 (volts/dB)
Notes: SLOPE controls the rate of change of the DC output voltage with respect to a 1 dB
change in signal power level.