Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, June, 2012)
39
RATE
Path: / CONFIGS MONOPULSE
Type: Data Editor
Syntax: RATE [= n] | [D]
Range: Integer: -1 .. 10000
Notes: RATE is the minimum number of milliseconds between the monopulse data
transmissions of START. If the value is -1, new data is sent only after receiving a
carriage return. NOTE: Also used by M&C in TRL-Emulation
RECEIVER OPERATION
Path: / CONFIGS OPERATION
Type: Sub Menu
Syntax: OPERATION
Notes: RECEIVER OPERATION configures how the Signal Processing Unit (SPU) will
process the signal.
REMOTE CONTROL
Path: / CONFIGS COM-PARAM REM-CONTROL
Type: Data Editor
Syntax: REM-CONTROL [= n] | [D]
Range: Integer: 0 .. 3
0 I/O INTF #1
1 PORT 1
2 PORT 2
3 PORT 3
Notes: REMOTE CONTROL selects which port on back panel is in control when the DTR is
in REMOTE mode. For remote M&C communications select PORT 1, 2, or 3 which
support serial protocols. To control the DTR via discrete digital I/O select I/O INTF
#1, which will allow a remote device (such as 7134ACU) to select a BEACON using
a cable connected to I/O INTERFACE #1 on the back panel and the
STORE/RESTORE BEACONS menus. The pinout of I/O INTERFACE # 1 includes:
Pins 5,18, GPIO 0, = Beacon 1 Input; Pins 6,19, GPIO 1, = Beacon 2 Input; Pins
7,20, GPIO 2, = Beacon 3 Input; Pins 8,21, GPIO 3, = Beacon 4 Input.