EasyManua.ls Logo

General Dynamics DIGITAL TRACKING RECEIVER - Analog Voltage Output (DAC) Setup; Setting up Beacons for 7134 Remote Control

General Dynamics DIGITAL TRACKING RECEIVER
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
3-12
CG-1220 DTR
3.5.1 Analog Voltage Output (DAC) Setup
1. Tune frequency to obtain desired signal at maximum power level.
2. Use DAC SETUP menu to establish VOLTAGE RANGE, MINIMUM REF POWER
LEVEL, and SLOPE.
DAC1 provides an analog DC voltage, proportional to signal level, on pins 1 and
14 (+OUT, -OUT) of I/O Interface #1 on the back panel.
A. The DC VOLTAGE RANGE of the Digital to Analog Converter (DAC) is set to
the default range of (0 to +10V). For Special uses, the voltage range can
alternatively be set to (-10 to +10V), or (-5 to+5V).
B. The SLOPE defaults to 0.3V/dB. SLOPE controls the rate of change of the DC
output voltage with respect to a 1 dB change in signal power level.
C. The MINIMUM REF POWER LEVEL establishes the power level corresponding
to the minimum DAC voltage. The default is –90 dBm which emulates GDST
“TRL” operation.
3. Check DAC1 output voltage (displayed on the front panel) and adjust MINIMUM
REF POWER LEVEL to obtain 8 VDC.
Note: If both DAC1 and DAC2 are enabled, the front panel display will report DAC1 voltage real-
time (not at specified DAC1 update rate). If DAC1 is disabled and DAC2 is enabled, front display
will report DAC2 voltage real-time; label will change to DAC2=. If DAC1 is enabled and DAC2 is
disabled, front display will report DAC1 voltage real-time. If DAC1 is disabled and DAC2 is
disabled, front display will not report anything (blank field).
3.5.2 Setting up Beacons for 7134 Remote Control
This brief summary outlines steps necessary to establish beacons which can be
accessed via remote control from GDST 7134 ACUs.
1. Set necessary parameters such as FREQUENCY, SLOPE, etc. See Section
4.2.5.4, BEACON SETUP for a complete list of beacon parameters.
2. Execute the STORE BEACON 1-4 menu at CONFIGS\BEACON-SETUP\STORE-
BEACONS. These current settings will be stored in the respective beacon
(BEACON 1-4).
3. Test by recalling BEACON 1-4.
4. The connection to the 7134 is via the I/O Interface #1. (Refer to Table 3-2)
5. To allow the 7134 ACU to select beacons, set CONFIGS\REMOTE CONTROL to
I/O Interface #1.

Table of Contents