Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, June, 2012)
29
LBAND-DEFAULTS (v1.19.07 or later)
Path: / CONFIGS BANDS BAND-1 LBAND-DEFAULTS
Type: Executable
Syntax: LBAND-DEFAULTS
Notes: Sets BAND-1 parameters to L-Band defaults. From v1.16.51 to v1.19.06, this
parameter was called IS-LBAND?.
LCD DISPLAY
Path: / CONFIGS TESTS LCD-TEST
Type: Data Editor
Syntax: LCD-TEST
Notes: LCD DISPLAY tests every pixel of the LCD by drawing lines in two alternating
patterns. The first pattern displays automatically; the second pattern will display
after a key-press. Press any key to exit test.
LCD CONTRAST
Path: / CONFIGS UI-OPTIONS CONTRAST
Type: Data Editor
Syntax: CONTRAST [= n]
Range: Real: 0 .. 30
Notes: Use LCD Contrast to adjust the contrast of the LCD display. Choose a value
between 0 (for least contrast) and 30 (for maximum contrast). Six is default value.
LEDS TEST
Path: / CONFIGS TESTS LEDS-TEST
Type: Executable
Syntax: LEDS-TEST
Notes: LEDS TEST blinks the top three status LED's four times. The Power LED does not
blink.