Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
28
INPUT ATTEN (v1.19.15 or later)
Path: / INPUT-ATTEN
Type: Data Editor
Syntax: INPUT-ATTEN [= n] | [D]
Range: Integer: 0 .. 15
0 – 0 dB 2 – 4 dB 4 – 8 dB 6 – 12 dB 8 – 16 dB 10 – 20 dB 12 – 24 dB 14 – 28 dB
1 – 2 dB 3 – 6 dB 5 – 10 dB 7 – 14 dB 9 – 18 dB 11 – 22 dB 13 – 26 dB 15 – 30 dB
Notes: INPUT ATTEN controls the attenuator in the RF front-end. The specified attenuation
is applied inside the RF front-end, after the first amplifier but before the first stage
mixer.
Also see: CONFIGS, RECEIVER OPERATION, ANALOG OUTPUTS, ATTENUATION.
INTERFACE OPTIONS
Path: / CONFIGS UI-OPTIONS
Type: Sub-Menu
Syntax: UI-OPTIONS
Notes: Allows control of options related to the DTR user interface.
I/O STATUS
Path: / STATUS I/O-STATUS
Type: Executable
Syntax: I/O-STATUS
Notes: Displays current I/O status info obtained from the I/O card. The I/O STATUS M&C
request returns the same information as the front panel I/O STATUS screen. Below
is an example from a terminal program. The content (especially for the internal
configuration values) and format is subject to change without notice:
>I/O-STATUS
INTF #1 IN= ~~ OUT= 00 INTF #2 IN= FF OUT= 00
BDC POWER IN= 2(3) BDC SELECTED=D(3) FAULTS=C ok
BDC POWER OUT=59(3) BDC SELECT=2(3)
SPDTX4 SW IN=FF(----) SPDTX4 SW OUT=AA (Hi22)
PLL VOLTAGES (VOLTS): PLL1=11.30 PLL2=1.70
TEMPERATURES (DEG F): LBFE=76.4 SPU=91.5
>
IS LBAND? (v1.16.51 through v1.19.06)
Notes: This parameter became LBAND-DEFAULTS in v1.19.07.