Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, June, 2012)
27
HIGH FREQ (OPTIONAL-Depending on RF Range)
Path: / CONFIGS BANDS BAND-3 HIGH-FREQ
Type: Data Editor
Syntax: HIGH-FREQ [= n] | [D]
Range: Real: 945.000 .. 13000.000 (v2.0.7 or later)
Real: 949.000 .. 13000.000 (v2.0.4 or earlier)
Notes: HIGH end FREQUENCY of the BDC that supports this band. Typical configurations:
S-band = 2800MHz
C-band = 4200MHz
X-band = 7750MHz
Ku-lo-band = 11700MHz
Ku-hi-band = 12750MHz
Ka-A = 18100, Ka-B = 19200, Ka-C = 20200, Ka-D = 21200, Ka-E = 22300
HIGH FREQ (OPTIONAL-Depending on RF Range)
Path: / CONFIGS BANDS BAND-4 HIGH-FREQ
Type: Data Editor
Syntax: HIGH-FREQ [= n] | [D]
Range: Real: 945.000 .. 13000.000 (v2.0.7 or later)
Real: 949.000 .. 13000.000 (v2.0.4 or earlier)
Notes: HIGH end FREQUENCY of the BDC that supports this band. Typical configurations:
S-band = 2800MHz
C-band = 4200MHz
X-band = 7750MHz
Ku-lo-band = 11700MHz
Ku-hi-band = 12750MHz
Ka-A = 18100, Ka-B = 19200, Ka-C = 20200, Ka-D = 21200, Ka-E = 22300
HIGH TEMP LIMIT (v1.16.51 or later)
Path: / CONFIGS UI-OPTIONS TEMP-LIMIT
Type: Data Editor
Syntax: TEMP-LIMIT [= n]
Range: 0 .. 140
Notes: This value, in degrees Fahrenheit, is used to trigger the TEMPERATURE ALARM
fault. The default value is 120 degrees F.