Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, June, 2012)
43
SET TIME
Path: / CONFIGS MEMORY DATE&TIME SET-TIME
Type: Data Editor
Syntax: SET-TIME [= n] | [D]
Range: Integer: 000000 to 235959 (Must be a valid time)
Notes: Changing this changes the current time ( in 24 hour format). Under the menu tree
shell the format is HHMMSS and all fields must be set.
SHELL
Path: / CONFIGS COMM-PARAM PORT-1 SHELL or
/ CONFIGS COMM-PARAM PORT-2 SHELL
Type: Data Editor
Syntax: SHELL [= n] | [D]
Range: Integer: 0 .. 4
0 Disabled
1 M&C Shell
2 Message Printer
3 Data Reader
4 72xx M&C Shell
Notes: SHELL determines the communications protocol used on this serial port. M&C Shell
provides monitor and control protocol support including status polling and system
configuration capability. 72xx M&C Shell provides TRL Monitor and Control
protocol support for status polling and system configuration by a 72xx ACU with
version 2 firmware. An ACU remote port set to DTR and a DTR set to 72xx M&C
SHELL will NOT communicate. Message Printer is a diagnostic tool which may be
used to record system events, when connected to a terminal program or a serial
printer.
SHELL (v 1.19.06 or later)
Path: / CONFIGS COMM-PARAM PORT-3 SHELL
Type: Data Editor
Syntax: SHELL [= n] | [D]
Range: Integer: 0 .. 1
0 Disabled
1 M&C Shell
Notes: SHELL determines the communications protocol used on this serial port. M&C Shell
provides monitor and control protocol support including status polling and system
configuration capability. The PORT-3 shell was added in v1.19.06.