Loading...
Appendix CDTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
24
FORCE CLEAR FAULTS
Path: / CONFIGS MEMORY CLEAR-FAULTS
Type: Executable
Syntax: CLEAR-FAULTS
Notes: FORCE CLEAR FAULTS forces the system to clear all faults, Faults that are set
periodically will appear again.
FREQ #1 IF OVERRIDE
Path: / CONFIGS MEMORY CALIBRATION IF-OVERRIDE F1-OVERRIDE
Type: Data Editor
Syntax: F1OVERRIDE [= n] | [D]
Range Integer: 0 .. 15
0 Automatic 4 829.6 8 836.0 12 842.4
1 824.8 5 831.2 9 837.6 13 844.0
2 826.4 6 832.8 10 839.2 14 845.6
3 828.0 7 834.4 11 840.8 15 847.2
Notes: Allows user selection of IF1 used by the L-Band front end for the current frequency.
IF1 specifies an approximate center for the digital filter within a 25MHz analog filter
centered at 836.5.
FREQ #2 IF OVERRIDE
Path: / CONFIGS MEMORY CALIBRATION IF-OVERRIDE F2-OVERRIDE
Type: Data Editor
Syntax: F2OVERRIDE [= n] | [D]
Range: Integer: 0 .. 15
0 Automatic 4 829.6 8 836.0 12 842.4
1 824.8 5 831.2 9 837.6 13 844.0
2 826.4 6 832.8 10 839.2 14 845.6
3 828.0 7 834.4 11 840.8
15 847.2
Notes: Allows user selection of IF1 used by the L-Band front end for the current frequency.
IF1 specifies an approximate center for the digital filter within a 25MHz analog filter
centered at 836.5.