BRAIN 17 22 732788 - Rev. A_1
ENGLISH
Display Basic Function
Default
FC
LIMIT SWITCH WHEN CLOSING
Lets you set or disable use of the closing limit switch on swing-leaves.
no = closing limit switches disabled
01 = the limit switch determines the stopping of motion
02 = the limit switch determines the start of deceleration
After having changed the value of this function, SETUP is required:
the card will signal error
14 (configuration error) until the SETUP is
performed again or until the previous value is restored.
no
Cd
DELAY FOR CLOSING LEAF (visualised only with the function Mn = 2):
Is the delay time for starting leaf 1 closing with respect to leaf 2. Makes it
possible to avoid overlapping of the two leaves.
Adjustable from
00 to 59 sec, in 1- second steps.
Next the value 59, the viewing changes to minutes and tenths of a second
(separated by a decimal point) and time is adjusted in 10-second steps up to
the maximum value of
1.3
minutes.
e.g.: if the display shows
1.2, the time is 1 min and 20 sec
05
bu
BUS G-WAY DEVICES ENTRY:
See the related paragraph.
no