25
GB
Nut is not removed by turning
Cause Remedy
Nut thread deformed Setting stroke or setting force too great
reduce (see item 4)
Removal period too short Hold activation button down for longer
Nut not automatically removed Keep holding down activation button until
nut has been automatically removed
Setting stroke or setting force not
reached
Keep holding down activation button until
nut has been automatically removed; if
necessary,relhydraulicoil
Increase network pressure (max. 7 bar)
Nut stuck on threaded mandrel Reduce setting force (see item 4)
Remove by pressing the removal button
7 or unscrew with the help of a hexagon
screw driver (see item 5.3)
Set nut is loose
Cause Remedy
Setting stroke "Y" too short Increase setting stroke (see item 4.1)
Setting force too low Increase setting force (see item 4.2)
Air pressure too low Increase air pressure to 5-7 bar
8. Notes on environment
Dispose of hydraulic waste oil according to current environmental regulations.
Observe regulations about dangerous substances!
9. Warranty
The applicable terms and conditions of guarantee shall apply and can be viewed under following
link: www.gesipa.com/agb