Ultrasonic Anemometer
ASCII Polar format
Units
Wind direction
Wind speed
<STX>A,121,000.08,M,00,<ETX>06
Start of
string
Unit identifier
Status
End of
string
Check sum
Where
Wind direction
In degrees relative to N (DDD)
Wind speed
In increments of 0.01 units (±MMM.MM)
All other parameters
See Section 5.7
ASCII UV format
ASCII Polled (UV and Polar)
When in the Polled mode, an output is only generated when the host system sends a Poll signal to the WindObserver
consisting of the WindObserver Unit Identifier that is, the relevant letter A Z.
The output formats are otherwise as described above.
The commands available in this mode are:
Description Command WindObserver response
WindObserver Unit Identifier A ….. Z Wind speed output generated
Enable Polled mode ? (None)
Disable Polled mode ! (None)
Request WindObserver Unit Identifier & A ….. Z (as configured)
Enter Configuration mode *<N> CONFIGURATION MODE
Where <N> is the unit identifier, if used in a multi-drop system then it is recommended that ID’s A to F and KMNP are not
used as these characters can be present in the data string.