Appendix K - WindObserver 65 Status Codes
WindObserver 65 is able to include a status code in each measurement string to confirm the reliability of the data or to
highlight any potential issues. A list of the status code is provided below.
Code Status Description
00 OK
No fault conditions detected in measurement period
60
OK and heating enabled
Sufficient samples in average period
A OK
NMEA data Acceptable
01 Axis 1 failed
Insufficient samples in average period on U axis
02 Axis 2 failed
Insufficient samples in average period on V axis
04 Axis 1 and 2 failed
Insufficient samples in average period on both axis
08 NVM error
NVM checksum failed, data could be uncalibrated
09 ROM error
ROM checksum failed, data could be uncalibrated
51
Measurement average
building
Data valid but warns that average period not reached when averaging used
(non-heat enabled units only)
62
Heating current tripped
or electronic failure
Valid data still output
63
Heater Thermistor open
circuit
Valid data still output
65
Heating element open
circuit
Valid data still output
V NMEA data void
Invalid data output

Related product manuals