36
Issue: 8 (Applies to firmware 2387 6.09 onwards)
Document number: 1390-PS-0039
5.9. NMEA Format
Identifier
Checksum
Delimiter
$ IIMWV, 120, R, 002.10, M, A* CC
Start of string
Instrument
type
Wind
measurement
Status
Check sum
Where
In degrees relative to North (DDD)
In increments of 0.01 units (±MMM.MM)
Kilometres per hour (kph)
F
Feet per minute (fpm)
Relative wind measurement
Exclusive OR of all characters between ‘$’ and ‘*’ reported as
ASCII hex.
A typical WindObserver 65 configuration suitable for NMEA would be:
B2, E1, F1, G0, K1, L1, M5, O1, P1, U1.
Consult specification NMEA 0183 version 3 (available on the web) www.nmea.org