LOGI CONTROL. Advanced mode 45
Cod. 523340
Rev. 10/1016
Purge drain
(Option available only on models with a double drainage kit installed on the machine and activated on the
configuration menu. Intervention reserved for the Authorised Technical Service)
The parameter only appears if a Purge Time other than 0 has been programmed in the previous parameter.
This option allows selecting the drain through which the purging water will be drained.
OPTIONS
MEANING
Pd-2
Purge water outlet via normally opened drain valve
Pd-3
Purge water outlet via normally closed drain valve or pump.
The ▲/▼ keys allows to activate and modify the purge time.
The key validates the selection on the display and allows the user to access the following programmable
function.
Network identifier
This parameter assigns a network identifier to the washer. This identifier enables the communication of the
washer with the environment through a protocol based on RS-485.
Selected option by default: Id-0.
OPTIONS
MEANING
Id-0
Disabled communication
Id-1..99
Enabled communication
For further information, see the Communication Protocol Instruction Manual.
The ▲/▼ keys allows to activate and modify the Network identifier.
Press key . The display shows Mod.
The ▲/▼ keys allow the user to access to other menus.
To exit the ADVANCED USE MODE press the START/STOP key.