LOGI CONTROL. Advanced mode 44
Cod. 523340
Rev. 10/1016
One-off wash phase temperature selection
This option allows the user to disable the possibility of modifying the temperature of the wash phase for the
program that is currently in use.
OPTIONS
MEANING
tS-0
Wash phase temperature selection disabled
tS-1
Wash phase temperature selection enabled
The ▲key allows the user to modify the option displayed.
The key validates the selection on the display and allows the user to access the following programmable
function.
Automatic weighing system (UK setting only)
This option enables the user to activate the automatic weighing system. HS models only.
OPTIONS
MEANING
JL-0
Automatic weighing system disabled
JL-2
Automatic weighing system enabled
The ▲key allows the user to modify the option displayed.
The key validates the selection on the display and allows the user to access the following programmable
function.
Proportional dosing time (UK setting only)
This option only appears if JL-2 has been programmed in the previous stage.
This modifies the dosing time in proportion to the bath level calculated according to the load detected.
OPTIONS
MEANING
dL-0
Proportional modification of the dosing time deactivated
dL-1
Proportional modification of the dosing time activated
The ▲ key allows the user to modify the option displayed.
The PRO key validates the selection on the display and allows the user to access the following programmable
function.
Hot water purge
(Option not available on HS-6008, MS-610, RMS610, EH020 and EM025)
The purge is an option that keeps the water inlet valve and the drain valve simultaneously open during the
programmed time, with the aim of purging the hot water pipe.
The purge function is only executed at the first phase of the program with water filling at a temperature equal to
or higher than 86 ºF (30 ºC).
Purge time: programmable in 5 second steps.
OPTIONS
MEANING
Pg-0
Purge disabled
P***
Purge time in seconds (maximum time 250 sec.)
The ▲/▼ keys allows to activate and modify the purge time.
The key validates the selection on the display and allows the user to access the following programmable
function.

Table of Contents

Other manuals for GIRBAU LOGI CONTROL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GIRBAU LOGI CONTROL and is the answer not in the manual?

GIRBAU LOGI CONTROL Specifications

General IconGeneral
BrandGIRBAU
ModelLOGI CONTROL
CategoryController
LanguageEnglish

Related product manuals