EasyManua.ls Logo

Glow-worm Easicom 28 - After Sales Service Settings; Installation Settings

Glow-worm Easicom 28
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0020140413_01 - 09/12 - Glow-worm
12.2 Installation settings
• Push in and hold the button for more than 7 seconds to
access the conguration menu. The screen displays "0".
• Press the
button 4 times. The screen displays "96". This is
the installer's password.
• Press
to validate. The screen displays a ashing and
alternating "d." and "00".
• Press
or button to access the parameter to modify.
• Press
button to modify the value of the parameter and
select with the or keys.
• Press
button to conrm and save the changes.
• Press and hold the
button for more than 7 seconds to
exit.
Code Parameter Unit Description Factory setting
Modiable
parameter
d.00 Maximum heating power kW
Choose a value: Easicom 24 > 8 to 18
and Easicom 28 > 8 to 24.
18 (Easicom 24)
24 (Easicom 28)
yes
d.01 Pump over-run time - heating min Choose a value between 2 and 60 5 yes
d.20 Maximum temperature setting for domestic hot water °C
The recommended maximum temperature
setting for DHW is 60°C. Choose a value
suitable for your needs.
60 yes
d.34 Speed of fan rpm
Fan speed is displayed between 0 and 99.
Multiply the display value by 100.
- no
d.36 Domestic hot water ow
l/
min.
Display domestic hot water ow. - no
d.40 Heating ow temperature °C Display the heating ow temperature. - no
d.41 Heating return temperature °C Display the heating return temperature. - no
d.43 Heating curve K
See the instructions for the external sensor
connected to the appliance.
1.2 yes
d.47 Exterior temperature °C
Display the temperature measured by the
external sensor.
- no
d.67
Time remaining before the end of the anti-cycle in
heating mode.
min.
Display the time remaining before the end of
the anti-cycle
- no
d.71 Maximum temperature setting for heating outlet °C Select a value between 50°C and 80°C. 75 yes
d.90 Detection of eBUS controller -
0 = Not detected
1 = Detected
- no
12.3 After Sales Service settings
• Press and hold the button for more than 7 seconds to
access the conguration menu. The screen displays "0".
• Press
or button and enter the After Sales Service
password.
• Press
to validate. The screen displays a ashing and
alternating "d." and "00".
• Press
or button to access the parameter to modify.
• Press
button to modify the value of the parameter and
select with the or keys.
• Press
button to conrm and save the changes.
• Press and hold the
button for more than 3 seconds to
exit the conguration menu.
Code Parameter Unit Description
Factory
setting
Modiable
parameter
d.08 Current state of the 230V room thermostat -
230V room thermostat :
0 = open (no heating),
1 = closed (heating mode).
- no
d.09 Flow temperature set point from external eBus control °C External eBus set value. - no
d.10 Heating pump status -
0 = o
1 = on
- no
d.16 Current state of the 24V room thermostat °C
0 = open (no heating),
1 = closed (heating mode)
- no
d.17 Flow or Return temperature control °C
Temperature regulation on ow (radiator) or return
(under-oor heating) temperature sensor.
0 yes
d.22 DHW demand active (tapping) -
0 = o
1 = on
- no
d.23 Central heating mode -
0 = CH not available (summer mode)
1 = CH available (winter mode)
- no
d.33 Speed setpoint of fan rpm
Fan speed is displayed between 0 and 99.
Multiply the displayed value by 100.
- no
INSTALLATION
- 24 -

Table of Contents

Other manuals for Glow-worm Easicom 28

Related product manuals