EasyManuals Logo

Glow-worm Easicom 28 Installation And Servicing

Glow-worm Easicom 28
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
0020145065_01 - 09/12 - Glow-worm
18.5.9 Gas valve
• Remove the burner door (11) refering to chapter "Dismantling
the burner door".
• Remove the two gas valve retaining screws (30).
• Remove the gas valve (31) and the gasket (32).
• Fit the new gas valve and the new gasket by repeating the
operations in reverse.
• After assembly test for gas tightness and purge in accordance
with the current issue of BS6891or in IE, the current edition of
I.S.813 “Domestic Gas Installations”.
• Check the combustion CO
2
.
18.5.10 Fan
• Remove the burner door (11) refering to chapter "Dismantling
the burner door".
• Remove the gas valve (31) (see previous paragraph).
• Loosen the 3 screws (38) located on the burner door (11).
• Remove the fan (33) and the gasket (35).
• Fit the new gasket (35).
• Screw the new fan to the burner door (11).
• After assembly test for gas tightness and purge in accordance
with the current issue of BS6891or in IE, the current edition of
I.S.813 “Domestic Gas Installations”.
18.6 Condensate trap
b
ATTENTION:
Condensate is mildly acidic. Wear protective gloves.
5
3
2
4
1
6
Key
1 Condensate reservoir
2 Condensate discharge
3 Condensate outlet
4 Condensateretainingscrew
5 Condensate trap
6 Hose
• Place a container under the condensate trap (5).
• Remove the condensate from the reservoir (1).
• Disconnect the condensation discharge (2).
• Disconnect the heat exchanger hose (6).
The condense trap will contain water, lift taking care not to spill
the water.
• Remove the condensate trap (5) using the retaining screw (4).
• IMPORTANT: Partially ll the condensate trap with water before
replacing. Start the siphon (3) and ll with water.
18.7 PCB
i
IMPORTANT:
When replacing the board refer to instructions supplied
with the spare part.
18.7.1 Main PCB
A
B
B
C
4
3
1
2
1
Key
1 Control panel
2 Rear panel
3 Retainings clips
4 Main PCB
• Remove the 24V and 230V connections.
• Remove the rear panel (2).
• Ease back the two PCB retaining clips (3) and withdraw the
PCB from the retaining lugs.
• Remove the electrical connections to the PCB (appliance
interface cable).
• When retting the rear panel, ensure the leads are not trapped.
MAINTENANCE
- 44 -

Table of Contents

Other manuals for Glow-worm Easicom 28

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Easicom 28 and is the answer not in the manual?

Glow-worm Easicom 28 Specifications

General IconGeneral
TypeCombi Boiler
Output28 kW
Energy Efficiency RatingA
MountingWall Mounted
Central Heating Output24 kW
Domestic Hot Water Output28 kW
Fuel TypeNatural Gas
Central Heating Max Pressure3 bar

Related product manuals