0020145065_01 - 09/12 - Glow-worm
17.6 Expansion vessel
1
2
Key
1 Expansion vessel
2 Expansion vessel pressure inlet
• Check the expansion vessel's supply pressure (see « Technical
Data » chapter) by means of the pressure inlet located on the
expansion vessel. Adjust the pressure if necessary.
• Following the installation of a new expansion vessel, ll and
purge the appliance or installation, if necessary.
17.7 Condensate trap
a
Warning:
condensate is mildly acidic. Use protective gloves.
5
3
2
4
1
6
Key
1 Condensate cleaning cap
2 Condensate pipe
3 Condensate outletv
4 Condensateretainingscrew
5 Condensate trap
6 Hose
• Place a container under the condensate trap (5).
• Remove the condensate from the reservoir (1).
• Disconnect the condensation discharge (2).
• Disconnect the heat exchanger hose (6).
The condense trap will contain water, lift taking care not to spill
the water.
• Remove the condensate trap (5) using the retaining screw (4).
• Clean the hose, the trap and the siphon, remove any
accumulated dirt.
• Reassemble the components, taking care to position the
gaskets correctly.
• Start the siphon (3) and ll with water.
MAINTENANCE
- 36 -

Table of Contents

Other manuals for Glow-worm Easicom 28

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Easicom 28 and is the answer not in the manual?

Glow-worm Easicom 28 Specifications

General IconGeneral
TypeCombi Boiler
Output28 kW
Energy Efficiency RatingA
MountingWall Mounted
Central Heating Output24 kW
Domestic Hot Water Output28 kW
Fuel TypeNatural Gas
Central Heating Max Pressure3 bar