6 Operation
16 Installation and maintenance instructions SUSTAIN ..c 0020200954_00
≤ 30 mm
NL
X1
230V~
RT
6. Carry out the wiring. ( Page 15)
7. Close the electronics box. ( Page 15)
8. Screw the supplied plug to a three-core mains connec-
tion cable that complies with the relevant standards.
9. Connect the plug for the mains connection cable.
10. Make sure that access to the mains connection is al-
ways freely available and is not covered or blocked by
an obstruction.
5.6.6 Connecting controllers to the electronic
system
X2
X22
X41
+
24V=
RT BUS
Burner
off
X106
BUS24 V
BUSRTB.off
B
ur
ner
off
R
T
24V
=
-
+
B
U
S
1
4
32
1 Safety thermostat for
floor-standing heating
2 24 V controller
3 eBUS controller or radio
receiver unit
4 Outside temperature
sensor, wired
1. Open the electronics box. ( Page 15)
2. Carry out the wiring. ( Page 15)
3. Connect the individual components depending on the
type of installation.
Conditions: If installing a multi-circuit controller.
Change the pump operating mode (d.18) from Eco (in-
termittent pump operating mode) to Comfort (continuous
pump operating mode).
Conditions: If you are connecting a controller (230 V).
≤ 30 mm
NL
X1
230V~
RT
Connect the controller to the main plug.
Remove the bridge from the plug 24V=RT.
4. Close the electronics box.
6 Operation
6.1 Using diagnostics codes
You can use the parameters marked as adjustable in the
table of diagnostics codes to adapt the product to the system
and customer requirements.
Overview of diagnostics codes ( Page 28)
6.1.1 Activating diagnostics codes
1.
Press and hold the button for 7 seconds.
is shown in the display.
2.
Press the or button to set the value.
The access code (96) is reserved for the competent
person.
The access code (35) is reserved for the customer
service.
3.
Press the button to confirm.
is shown in the display.
6.1.2 Setting a diagnostics code
1.
Press the or button to select the diagnostics
code.
2.
Press the button to confirm.
The value and/or status of the diagnostics code is
shown in the display.
3.
Press the or button to set the value.
4. If you allow the value to flash for three seconds, the
setting is automatically confirmed.
is shown in the display for 1 second.
Note
You can manually confirm the setting at any
time by pressing and holding the button
for less than 3 seconds.