Start-up 7
0020200954_00 SUSTAIN ..c Installation and maintenance instructions 17
5. Proceed accordingly for all parameters that need to be
changed.
6.
Press and hold the button for 3 seconds to finish
configuring the diagnostics codes.
The display switches to the basic display.
6.2 Displaying the status codes
The status codes display the product's current operating
status.
Status codes Overview ( Page 32)
6.2.1 Activating the status codes display
1.
Hold the button down for more than 7 seconds.
S.XX is shown on the display, followed by the heat-
ing flow temperature, the internal system pressure
and the cylinder temperature (depending on the ver-
sion).
2.
Press the button to exit this menu.
The display switches to the basic display.
6.3 Using check programmes
By activating various check programmes, you can trigger
various special functions on the product.
Check programmes Overview ( Page 28)
6.3.1 Calling up the check programmes
1.
Hold the button down for more than 5 seconds.
All symbols are shown in the display.
is shown in the display.
2.
Press and hold the button for five seconds.
is shown in the display.
3.
Press the or button to select the check
programme.
4.
Press the button to confirm.
on is shown in the display and the programme
starts.
5.
Press the and buttons at the same time whilst
running a check programme.
The heating water temperature and the filling pres-
sure for the heating installation are shown altern-
ately in the display.
6.
Press the button to return to the check programme.
The display shows the check programme.
7.
Press the button to finish the check programme.
OFF is shown in the display.
8.
Press and hold the button for 3 seconds to finish
the check programmes.
End is shown in the display.
The display switches to the basic display.
Note
If you do not press any button for 15 minutes,
the current programme is automatically can-
celled and the basic display is shown.
6.3.2 Displaying the pressure and temperature of
the heating during a check programme
1.
Press the buttons simultaneously.
Display the filling pressure in the heating installation.
Display the heating flow temperature.
2.
Press the button to display the check programme
currently running.
7 Start-up
7.1 Carrying out the initial start-up
Initial start-up must be carried out by a customer service
technician or an authorised competent person using the first-
commissioning-checklist. The first-commissioning-checklist
in the appendix ( Page 40) of the installation instructions
must be filled in and stored carefully along with the unit's
documentation.
Carry out the initial start-up using the first-commission-
ing-checklist in the appendix.
Fill out and sign the first-commissioning-checklist.
7.2 Checking the type of gas
Make sure that the product is set up correctly by checking
the type of gas. This ensures optimum combustion quality.
Check the type of gas as part of routine product mainten-
ance work when replacing components, carrying out work
on the gas route and carrying out a gas conversion.
7.3 Checking the factory setting
The product's combustion has been factory tested and is
preset for operation with the gas group indicated on the iden-
tification plate.
Check the information about the type of gas indicated on
the identification plate and compare this with the type of
gas available at the installation location.
Conditions: The product design is not compatible with the local gas
group
Do not start up the product.
Conditions: The product design is compatible with the local gas group
Proceed as described below.