Appendix
0020200954_00 SUSTAIN ..c Installation and maintenance instructions 31
Setting level Values
Unit Increment, select, explanation
Default set-
ting
Own setting
Min. Max.
d.60 Number of blocks by the
temperature sensor
Current value Not
adjustable
d.61 Number of successful
ignitions
Current value Not
adjustable
d.62 Night set-back 0 30 1 0 Adjustable
d.64 Average burner ignition
time
Current value s Not
adjustable
d.65 Maximum burner ignition
time
Current value s Not
adjustable
d.66 Activation of the warm
start function for hot water
off = Function deactivated
on = Function activated
1 Adjustable
d.67 Remaining burner anti-
cycling time (setting under
d.02)
Current value min Not
adjustable
d.68 Number of unsuccessful
ignitions at 1st attempt
Current value Not
adjustable
d.69 Number of unsuccessful
ignitions at 2nd attempt
Current value Not
adjustable
d.70 Function of the diverter
valve
0 2 0 = Normal operating mode (DHW
and heating mode)
1 = Mid-position (parallel operation)
2 = Permanent heating mode position
0 Adjustable
d.71 Maximum heating flow set
target temperature
45 80 1 75 Adjustable
d.73 Correction of the hot wa-
ter warm start temperature
-15 5 1 0 Adjustable
d.75 Maximum cylinder reheat-
ing time
20 90 min 1 45 Adjustable
d.77 Max. cylinder reheating kW 1
Section "Technical data"
Adjustable
d.80 Running time in heating
mode
Current value h Not
adjustable
d.81 Running time in hot water
handling mode
Current value h Not
adjustable
d.82 Number of burner igni-
tions in heating mode
Current value Number of ignitions = Display value x
100
Not
adjustable
d.83 Number of burner igni-
tions in hot water handling
mode
Current value Number of ignitions = Display value x
100
Not
adjustable
d.84 Maintenance in 0 3000 h Number of hours = Display value x 10 300 Not
adjustable
d.85 Increase in the min. out-
put (heating and hot water
handling mode)
kW 1
Section "Technical data"
Adjustable
d.88 Flow rate limit value for
ignition in hot water handling
mode
0 1 0 = 1.5 l/hr (no delay)
1 = 3.7 l/hr (2 s delay)
0 Adjustable
d.90 Status of the eBUS room
thermostat
Current value off = Not connected
on = Connected
Not
adjustable
d.91 Status DCF77 Current value Not
adjustable
d.93 Setting the product code 0 99 1 Adjustable
d.94 Delete fault list 0 1 off = No
on = Yes
Adjustable
d.95 Software versions 1 = Main PCB
2 = Interface PCB
Adjustable