SPECIAL CODES
Continued from previous page.
ART 7T/G2+ MONITOR
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the2
master monitor).
Automatic OFFAlways ON Always Factory setting
1450 1451 1452 1450 (automatic).
Activation times of the outputs (Door panel ). (Configure only on the master monitor).2
Factory setting
Relay 1 From to1200 (0,5s) 1219 (10s) 1205 (3s)
Rel 1300 (0,5s) 1319 (10s) 1305 (3s)ay 2 From to
Configuration of the remote activation button (Door panel ). (Configure only on the master monitor).Relay1 2
Factory setting
Delay From to1400 (0,5s) 1419 (10s) 1403 (2s)
Configuration of the remote activation button (Door panel ). (Configure only on the master monitor).Relay2 2
Factory setting
Delay From 5 to 5 51 00 (0,5s) 1 19 (10s) 1 03 (2s)
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the3
master monitor).
Automatic OFFAlways ON Always Factory setting
2450 2451 2452 2450 (automatic).
Activation times of the outputs (Door panel ). (Configure only on the master monitor).3
Factory setting
Relay 1 From to2200 (0,5s) 2219 (10s) 2205 (3s)
Rel 2300 (0,5s) 2319 (10s) 2305 (3s)ay 2 From to
Configuration of the remote activation button (Door panel ). (Configure only on the master monitor).Relay1 3
Factory setting
Delay From to2400 (0,5s) 2419 (10s) 2403 (2s)
Configuration of the remote activation button (Door panel ). (Configure only on the master monitor).Relay2 3
Factory setting
Delay From 5 to 5 52 00 (0,5s) 2 19 (10s) 2 03 (2s)
LED lights for night viewing (Door panel ) during a call or communication process. (Configure only on the4
master monitor).
Automatic OFFAlways ON Always Factory setting
3450 3451 3452 3450 (automatic).
Activation times of the outputs (Door panel ). (Configure only on the master monitor).4
Factory setting
Relay 1 From to3200 (0,5s) 3219 (10s) 3205 (3s)
Rel 3300 (0,5s) 3319 (10s) 3305 (3s)ay 2 From to
Configuration of the remote activation button (Door panel ). (Configure only on the master monitor).Relay1 4
Factory setting
Delay From to3400 (0,5s) 3419 (10s) 3403 (2s)
Configuration of the remote activation button (Door panel ). (Configure only on the master monitor).Relay2 4
Factory setting
Delay From 5 to 5 53 00 (0,5s) 3 19 (10s) 3 03 (2s)
To define the light up duration time from 1 to 99 seconds (SAR-G2+ Relay). ( ).
Configure only on the master monitor
Factory setting
From 1801 (1s) to 1899 (99s) 1803 (3s)
To define the light up delay time from 0 to 99 seconds (SAR-G2+ Relay). ( ).
Configure only on the master monitor
Factory setting
From 1900 (0s) to 1999 (99s) 1900 (0s)
Restore the door panel(s) Soul Access with the master code to factory default: 1234".
All door panels Door panel 1 Door panel Door panel Door panel 42 3
8000 8001 8002 8003 8004
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
*
( )
Continued overleaf