7
SOUL ANELP
Configuration switches (R)
All switches are factory set to OFF.
Configuration changes should be made with the equipment turned off. If they are performed with the equipment
turned on, disconnect it for 10 seconds after any modification.
Note: Configuration switches for the SOUL/1, SOUL/2, and SOUL/4 with version V04 and next.
Switch 1 .and 2
Defines the door panel address.
Door panel 1
1
apartment
* .Same value as setting them to ON-ON
2 apartments
Switches and3 4.
2: the two bottom buttons call apartment 1,
the two top buttons call apartment 2.
Define the number of apartments:
4: .each button calls one apartment
1: all buttons call apartment 1.
4
apartments
Setting the audio level
If the audio volume on the door panel after starting up the device is not adequate, use the volume control
potentiometer (S). This setting affects the communication and confirmation tone audio level.
BUS BUS CV- CV+ AP+
C NA GND CCTV AP-
ON
1 2 3 4
SOU S5110/ART 7 VIDE ENTL O DOOR RY SYSTEM KIT
S
Door panel 2
OFF-OFF
* -OFF OFF
O -OFFN
ON OFF- OFF ON-
ON
1 2
3 4
ON
1 2
3 4
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
OFF-ON O -ONN
ON
1 2
3 4
ON
1 2
3 4
Door panel 3 Door panel 4