  • C
    Cheryl RoseAug 29, 2025
    What to do if Goodwe GW15K-ET shows Internal Comm Loss?
    • P
      Patrick HernandezAug 30, 2025
      If your Goodwe Inverter is experiencing an Internal Comm Loss, which can be caused by a frame format error, parity checking error, CAN bus offline, hardware CRC error, incorrect send/receive control bit, or transmission to an unauthorized unit, try disconnecting the AC output switch and DC input switch, then reconnect them after 5 minutes.
  • R
    Ryan GreenAug 29, 2025
    What does Anti-islanding mean on my Goodwe GW15K-ET?
    • J
      Jared GrantAug 29, 2025
      If your Goodwe Inverter shows an Anti-islanding error, it indicates that the utility grid is disconnected, according to safety regulations, but the grid voltage is maintained due to the loads. Check whether the utility grid is disconnected.
  • F
    Felicia DavisAug 28, 2025
    How to resolve PV Input Overvoltage on Goodwe Inverter?
    • M
      Marc HamiltonAug 28, 2025
      If your Goodwe Inverter is showing PV Input Overvoltage, it means the PV array configuration is incorrect, and too many PV panels are connected in series in the PV string. Check the serial connection of the PV array. Ensure that the open circuit voltage of the PV string is not higher than the maximum operating voltage of the inverter.
  • T
    Tony Stone DDSSep 12, 2025
    What causes PV Input Overvoltage on Goodwe GW15K-ET?
    • B
      Bradley BrownSep 12, 2025
      A 'PV Input Overvoltage' error on your Goodwe Inverter indicates that the PV array configuration is not correct, meaning too many PV panels are connected in series in the PV string. You should check the serial connection of the PV array to ensure that the open circuit voltage of the PV string is not higher than the maximum operating voltage of the inverter.
  • C
    Christopher ArcherSep 14, 2025
    How to fix GFCI HCT Check abnormal on Goodwe GW15K-ET Inverter?
    • J
      James MillerSep 14, 2025
      To address a 'GFCI HCT Check abnormal' error on your Goodwe Inverter, disconnect the AC output switch and DC input switch, then reconnect them after 5 minutes. This error indicates that the sampling of the GFCI HCT is abnormal.
  • A
    Amy MahoneySep 18, 2025
    How to fix low insulation resistance on Goodwe Inverter?
    • H
      henry68Sep 18, 2025
      If the Goodwe Inverter indicates low insulation resistance, it's likely that the input insulation impedance has become low during operation. To resolve this, check the impedance between the PV string and PE to ensure it is not too low. If the problem persists, further inspection may be needed.
  • K
    Keith SmithAug 27, 2025
    What does Grid Rapid Overvoltage mean on Goodwe Inverter?
    • I
      ifieldsAug 27, 2025
      If your Goodwe Inverter is showing Grid Rapid Overvoltage, it means that the grid voltage is abnormal or ultra-high. If the problem occurs occasionally, the utility grid may be temporarily abnormal. The inverter will recover automatically after detecting that the utility grid is normal. If the problem occurs frequently, check whether the grid voltage is within the allowed range and contact the local power company if it exceeds the permissible range.
  • T
    Traci JohnsonAug 26, 2025
    Why is my Goodwe GW15K-ET Inverter showing Grid Undervoltage?
    • J
      joseph46Aug 26, 2025
      If your Goodwe Inverter is showing a Grid Undervoltage error, it might be because the grid voltage is lower than the permissible range, or the duration of low voltage exceeds the LVRT requirement. If this occurs occasionally, it could be a temporary issue with the utility grid, and the inverter should recover automatically once the grid returns to normal. If the problem occurs frequently, check whether the grid voltage is within the permissible range. Also, ensure the AC breaker and the output cables are securely and correctly connected.
  • B
    Brian BoydAug 26, 2025
    What causes Grid Overfrequency on a Goodwe GW15K-ET?
    • M
      Melanie WatsonAug 26, 2025
      If your Goodwe Inverter displays a Grid Overfrequency error, it's likely due to a utility grid exception where the actual grid frequency exceeds the local grid standard's requirements. If this occurs occasionally, it may be a temporary issue, and the inverter should recover automatically once the grid frequency returns to normal. However, if the problem happens frequently, verify that the grid frequency is within the permissible range. If it exceeds the limit, contact your local power company.
  • M
    Maureen ChapmanAug 25, 2025
    Why does my Goodwe GW15K-ET show Grid Overvoltage?
    • R
      Rachel GriffithAug 26, 2025
      If your Goodwe Inverter is showing a Grid Overvoltage error, it could be because the grid voltage exceeds the acceptable range, or the duration of high voltage surpasses HVRT requirements. If this happens occasionally, it may be a temporary issue with the utility grid, and the inverter should automatically recover once the grid voltage returns to normal. If the problem occurs frequently, verify that the grid voltage is within the permissible range. If it's not, contact your local power company. Also, ensure the AC breaker and output cables are securely and correctly connected.

Summary

Safety Precautions

General Safety Guidelines

Essential safety rules for handling and operating the inverter.

PV String Safety

Safety measures for connecting and managing photovoltaic strings.

Inverter Safety

Critical safety instructions specific to the inverter's operation.

Product Introduction

Installation Guide

Installation Site Requirements

Environmental and location criteria for inverter installation.

Moving and Installing the Inverter

Step-by-step instructions for physical mounting.

Electrical Connections

System Wiring Overview

Diagrams illustrating system electrical connections.

Electrical Connection Safety

Crucial safety rules for making electrical connections.

DC Input (PV) Connection

How to connect photovoltaic strings to the inverter.

Battery Cable Connection

Detailed steps for connecting the battery system.

AC Cable Connection

Procedures for connecting the inverter to the AC power source.

Equipment Commissioning

Pre-Power-On Checks

Essential checks before energizing the equipment.

Power-On Procedure

Steps to safely turn on the inverter system.

System Configuration

Maintenance and Troubleshooting

Powering Off the Inverter

Safe procedure for shutting down the inverter for maintenance.

Troubleshooting Common Issues

Solutions for frequently encountered inverter faults.