Questions and Answers

  • C
    Cheryl RoseAug 29, 2025
    What to do if Goodwe GW15K-ET shows Internal Comm Loss?
    • P
      Patrick HernandezAug 30, 2025
      If your Goodwe Inverter is experiencing an Internal Comm Loss, which can be caused by a frame format error, parity checking error, CAN bus offline, hardware CRC error, incorrect send/receive control bit, or transmission to an unauthorized unit, try disconnecting the AC output switch and DC input switch, then reconnect them after 5 minutes.
  • J
    Joyce CarterAug 30, 2025
    What causes Abnormal GFCI 30mA error on Goodwe GW15K-ET Inverter?
    • R
      rodriguezdavidAug 30, 2025
      If your Goodwe Inverter shows an Abnormal GFCI 30mA error, it indicates that the input insulation impedance becomes low when the inverter is working. If this occurs occasionally, it may be due to a cable exception, and the inverter will recover automatically once the problem is resolved. If the problem occurs frequently or persists, check whether the impedance between the PV string and PE is too low.
  • Z
    zgonzalezAug 30, 2025
    What does LVRT Undervoltage mean on Goodwe GW15K-ET Inverter?
    • K
      Kelly BarronAug 31, 2025
      If your Goodwe Inverter displays LVRT Undervoltage, it indicates a utility grid exception where the duration of the utility grid exception exceeds the set time of LVRT. If this problem occurs occasionally, the utility grid may be temporarily abnormal, and the inverter will recover automatically once the grid returns to normal.
  • J
    jonathankellyAug 31, 2025
    How to fix AC HCT Check abnormal error on Goodwe GW15K-ET Inverter?
    • D
      Daniel BaileyAug 31, 2025
      If your Goodwe Inverter displays an AC HCT Check abnormal error, indicating that the sampling of the AC HCT is abnormal, try disconnecting the AC output switch and DC input switch, then reconnect them after 5 minutes.
  • P
    patricia56Aug 25, 2025
    Why is my Goodwe Inverter device offline on the APP?
    • S
      sbarrettAug 25, 2025
      If the APP displays that your Goodwe Inverter is offline, it could be due to a communication failure or equipment failure. Check whether the quantity of parallel machines in the system is the same with the actual connected ones. If it is, get the SN of the corresponding offline inverter from the equipment list, and troubleshoot the corresponding inverter according to its user manual. Check whether the communication connection of the equipment is normal, with no loose, aging or wrong connection, etc.
  • C
    Cassandra SmithSep 1, 2025
    Why does my Goodwe Inverter show Relay Check abnormal?
    • G
      Gabriel PotterSep 1, 2025
      If your Goodwe Inverter displays a Relay Check abnormal error, which can be caused by a relay being abnormal or short-circuited, an abnormal control circuit, or an abnormal AC cable connection (like a virtual connection or short circuit), try disconnecting the AC output switch and DC input switch, then reconnect them after 5 minutes.
  • A
    acampbellSep 1, 2025
    How to troubleshoot Flash Fault on Goodwe Inverter?
    • L
      Lisa Williams DDSSep 2, 2025
      If your Goodwe Inverter displays a Flash Fault, indicating that the internal Flash storage is abnormal, try disconnecting the AC output switch and DC input switch, then reconnect them after 5 minutes.
  • M
    Megan ScottSep 2, 2025
    What does Large DC of AC current L1 mean on Goodwe GW15K-ET?
    • S
      Stephanie ChungSep 2, 2025
      If your Goodwe Inverter shows Large DC of AC current L1, it means that the DC component of the output current exceeds the safety or default range. If the problem is caused by an external fault like a utility grid exception or frequency exception, the inverter will recover automatically after solving the problem.
  • T
    timothywilsonSep 2, 2025
    What to do if my Goodwe GW15K-ET Inverter has a DC Arc Fault?
    • S
      Steven SullivanSep 3, 2025
      If your Goodwe Inverter displays a DC Arc Fault, it could be because the DC terminal is not firmly connected or the DC cable is broken. Refer to the Quick Installation Guide and check whether the cables are connected properly.
  • R
    Ryan MillerSep 3, 2025
    How to fix PV Continuous Hardware Overcurrent on Goodwe GW15K-ET?
    • L
      lee48Sep 3, 2025
      If your Goodwe Inverter displays PV Continuous Hardware Overcurrent, it could be caused by an improper PV configuration or hardware damage. Try disconnecting the AC output switch and DC input switch, then reconnect them after 5 minutes.

Summary

Safety Precautions

General Safety Guidelines

Essential safety rules for handling and operating the inverter.

PV String Safety

Safety measures for connecting and managing photovoltaic strings.

Inverter Safety

Critical safety instructions specific to the inverter's operation.

Product Introduction

Installation Guide

Installation Site Requirements

Environmental and location criteria for inverter installation.

Moving and Installing the Inverter

Step-by-step instructions for physical mounting.

Electrical Connections

System Wiring Overview

Diagrams illustrating system electrical connections.

Electrical Connection Safety

Crucial safety rules for making electrical connections.

DC Input (PV) Connection

How to connect photovoltaic strings to the inverter.

Battery Cable Connection

Detailed steps for connecting the battery system.

AC Cable Connection

Procedures for connecting the inverter to the AC power source.

Equipment Commissioning

Pre-Power-On Checks

Essential checks before energizing the equipment.

Power-On Procedure

Steps to safely turn on the inverter system.

System Configuration

Maintenance and Troubleshooting

Powering Off the Inverter

Safe procedure for shutting down the inverter for maintenance.

Troubleshooting Common Issues

Solutions for frequently encountered inverter faults.