Maintaining Item Maintaining Period
Check whether the locking brackets are secured, tighten it if not. Once every 6 months
Check whether the outer enclosure is broken. Repair the painting
or contact after-sales service if there is any broken.
Once every 6 months
Check whether there is an exposed cable. Replace the exposed
cable or contact the after-sales service for help.
Once every 6 months
Check whether there is any dust around the battery module. Clean
the dust if there is any to avoid aecting heat dissipation.
Once every 6 months
Check whether there is any liquid or pest near the battery to avoid
intrusion in a long term.
Once every 6 months
WARNING
Contact after-sales service for help if you nd any problems that may inuence the battery
or the hybrid inverter. Disassemble without permission is strictly forbidden.
Contact after-sales service for help if the copper conductor is exposed. Do not touch or
disassemble privately because the high voltage danger exists.
In case of other emergencies, contact after-sales service as soon as possible. Operate
following the instructions or wait for the after-sales service personnel.
8 Maintenance
Follow the steps below to power o the battery system to prevent the system from being
damaged.
Method one:
Step 1: Turn o the inverter in the system following the instructions in the user manual of the
inverter.
Step 2: Disconnect the air switch, and make sure that the SOC indicator and multifunction
button indicator of the PCU are o.
Method two:
Step 1: Turn o the inverter in the system following the instructions in the user manual of the
inverter.
Step 2: Long press the multifunction button indicator for more than 15s, and make sure that the
SOC indicator and multifunction button indicator of the PCU are o.
8.1 Power OFF the Battery System