Instructions
XP Mix Manifold Kits
For mixing two component reactive materials with plural-component sprayers.
For professional use only.
See page 3 for model information including
working pressure and approvals.
Important Safety Instructions
Read all warnings and instructions in this
manual and in your proportioner manual
before using the equipment. Save these
instructions.
3A0590R
EN
24M398 Shown

Questions and Answers

  • M
    Matthew Dickerson PhDAug 7, 2025
    What to do if the Graco Service Equipment spray pattern is developing tails?
    • M
      Mr. Robert MillerAug 7, 2025
      Tailing in the spray pattern of your Graco Service Equipment can occur due to several reasons. It may be caused by a static mixer or whip hose plugging up, low pressure from the proportioner, cold material, too much pressure drop, insufficient air supply (possibly due to a small air hose or compressor), motor icing, or dirty filters in the pumps or spray gun. You may need to clean the static mixers, check air supply pressure, increase heat, use larger hoses or more heat, use de-ice bleed air on the motor, wait for the motor to thaw or clean the filters.
  • L
    Lori Baker MDAug 11, 2025
    What to do if mixed fluid will not flush out of Graco Service Equipment?
    • M
      michael25Aug 12, 2025
      If the mixed fluid won't flush out of your Graco Service Equipment, it could be due to several reasons. The fluid might have hardened in the static mixers or whip hose, the solvent supply container might be empty, or the solvent being used might not be compatible with the fluid. Try cleaning with a compatible solvent or refilling the solvent supply container and if this does not work, switch to a compatible solvent.
  • C
    Christopher HendersonAug 16, 2025
    Why is there little or no hardener output from my Graco Service Equipment?
    • S
      Stephanie SotoAug 16, 2025
      If your Graco Service Equipment has little or no hardener output, it may be because the fluid inlet is plugged, the fluid container is empty or the hardener screen is plugged. To resolve this, try cleaning the inlet to remove any obstruction or refilling the fluid container.
  • H
    hernandezisabellaAug 20, 2025
    How to troubleshoot little or no resin output in Graco Service Equipment?
    • D
      Debra CareyAug 20, 2025
      If you're experiencing little to no resin output from your Graco Service Equipment, the fluid inlet might be plugged, or the fluid container could be empty. To fix this, clean the inlet to remove any obstruction, or refill the fluid container.
  • J
    Jessica KellyAug 25, 2025
    Why is the hardener pressure higher than normal in my Graco Service Equipment?
    • S
      Stephanie MartinezAug 25, 2025
      If the hardener pressure is higher than normal in your Graco Service Equipment, it could be due to the hardener being cold or a restrictor or screen plugging up. To address this, correct the heat problem or open the restrictor or clean the screen.
  • K
    Kyle SavageAug 29, 2025
    What causes low hardener pressure in Graco Service Equipment?
    • X
      xpetersonAug 29, 2025
      If the hardener pressure is lower than normal in your Graco Service Equipment, it could be because the resin is cold and the flow rate is low, or the hardener restrictor is worn. Try to correct the heat problem.
  • M
    michaeldavisSep 2, 2025
    What causes off ratio condition in Graco Service Equipment after increasing spray pressure?
    • K
      Kevin FullerSep 2, 2025
      An off-ratio condition in your Graco Service Equipment after increasing spray pressure with a remote mix manifold can be caused by hoses not being volume balanced. To resolve this, volume balance A and B remote material hoses closer to the volume mix ratio.

Graco 24M398 Specifications

General IconGeneral
BrandGraco
Model24M398
CategoryService Equipment
LanguageEnglish

Related product manuals