1
Apply lubricant to o-rings and cartridge o-ring and end seal.
Apply taper thread pipe sealant to all non-swiveling threads
except cartridge (2) and needle (12).
Apply anaerobic medium thread locker to external threads.
Torque to 125 ft-lbs (70 N•m).
Turn stem fully into manifold. Then back out two turns and
lock in place.
Large end of inside taper faces out.
Push assembly hard against a flat surface to snap retainer
seal (2f) in place.
Shipped loose. Use when a mix manifold is replaced on a
Series A XP Plural-Component Sprayer.