Operation
3A4587D Operation, Repair, Parts 13
c. Set throttle to fast.
d. Set engine switch to ON.
e. Pull starter cord.
f. After engine starts, move choke to open.
g. Set throttle to slow.
7. Set pump switch to ON. Increase pressure enough
to start pump. Allow fluid to circulate for 15 seconds.
8. Turn pressure down, close prime valve. Disengage
gun trigger lock.
9. Hold gun against grounded metal flushing pail. Trig-
ger gun and increase fluid pressure slowly until
pump runs smoothly.
ti5250a
ti27619a
ti27620b
ti27766b
ti5250b
NOTICE
Do not run pump without fluid flow. Damage to
packings can occur.
ti30076a
ti30077a
ti30079a