18 3A4587D Operation, Repair, Parts
Clean-up
1. Perform Pressure Relief Procedure.
See Pressure Relief Procedure, page 8.
2. Remove Rac Guard and Rac Tip.
3. Unscrew cap, remove filter. Assemble without filter.
Clean filter.
4. Clean gun filter, Rac Guard and Rac Tip in flushing
fluid. See Flushing Recommendations, page 21.
5. Remove siphon tube set from paint and place in
flushing fluid. Use water or pump conditioner for
water-base paint and mineral spirits for oil-base
paint.
6. Turn engine ON and start engine. Set pump switch
ON.
ti30308a