Startup
18 334558D
Startup
1. Place suction tube and drain tube in
grounded metal pail partially filled with
flushing fluid. Attach ground wire to pail
and to earth ground.
2. Turn prime valve down to DRAIN posi-
tion. Turn pressure control counter-
clockwise to lowest pressure.
3. Set hydraulic pump valve OFF.
4. If using electric motor, plug cord into
outlet and turn switch to ON.
5. If using gasoline engine, start engine.
a. Move fuel valve to open.
b. Move choke to closed.
c. Set throttle to fast.
d. Set engine switch to ON.