Operation
Pressure Pressure
Pressure
Relief Relief
Relief
Procedure Procedure
Procedure
FollowthePressureReliefProcedure
wheneveryouseethissymbol.
Thisequipmentstayspressurizeduntilpressure
isrelievedmanually.Tohelppreventserious
injuryfrompressurized󰘱uid,suchassplashing
intheeyesoronskin,followthePressureRelief
Procedurewhenyoustoppumpingandbeforeyou
clean,check,orservicetheequipment.
1.Removepowerfromthesystem.
2.Openthedispensingvalve,ifused.
3.Openthe󰘱uiddrainvalve(L),ifused,torelieve
󰘱uidpressure.Haveacontainerreadytocatch
thedrainage.
4.Shutofftheairsupplytothepump.
5.Backoutcentersectionregulatortorelieveair
pressureincentersection.
Pump Pump
Pump
Shutdown Shutdown
Shutdown
Attheendoftheworkshiftandbeforeyoucheck,
adjust,clean,orrepairthesystem,followthe
PressureReliefProcedure,page20.