EasyManua.ls Logo

Graco HUSKY 716 - User Manual

Graco HUSKY 716
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
308983
Rev. B
First choice when
quality counts.
9090A
INSTRUCTIONS–PARTS LIST
INSTRUCTIONS
See instruction manual 308981 for
important warnings and information.
READ AND KEEP FOR REFERENCE.
For converting METAL Husky 715 air-operated diaphragm pumps
Husky 716 Air Motor Retrofit Kits
Part No. 241631
with standard air motor
Part No. 241664
with remote-operated air motor
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
COPYRIGHT 1999, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001

Other manuals for Graco HUSKY 716

Questions and Answers

  • K
    knightshaneSep 9, 2025
    What to do if exhaust air from my Graco Water Pump contains fluid?
    • S
      shawmarieSep 10, 2025
      If the exhaust air from your Graco Water Pump contains fluid, there are a few potential causes. The diaphragm may be ruptured and needs replacing. Also, the fluid-side diaphragm plates might be loose, requiring you to torque the diaphragm shaft screws to 80 to 90 in-lb (9 to 10 N-m) at 100 rpm maximum. Another possible reason is that the U-cup diaphragm shaft seals are worn and need replacement.
  • L
    Louis FordSep 12, 2025
    What causes my Graco Water Pump to cycle at stall or fail to hold pressure?
    • O
      Olivia CookeSep 12, 2025
      If your Graco Water Pump cycles at stall or fails to hold pressure at stall, it could be that the duckbill valves are leaking and need replacement. It could also be that the U-cup diaphragm shaft seals are worn and need replacing.
  • J
    Jennifer MillerSep 14, 2025
    How to troubleshoot a Graco HUSKY 716 that will not cycle?
    • B
      Brandon DavidsonSep 14, 2025
      If your Graco Water Pump will not cycle, or cycles once and stops, the air valve might be stuck or dirty. Clean or service the air valve and use filtered air.
  • E
    Erica MuellerSep 16, 2025
    Why is my Graco HUSKY 716 exhausting air from vee clamps?
    • G
      Gina GonzalesSep 16, 2025
      If your Graco Water Pump is exhausting air from the vee clamps, the vee clamps may be loose. Torque the vee clamp nuts to 80 to 90 in-lb (9 to 10 N-m).

Summary

Husky 716 Air Motor Retrofit Kits

Installation Guide

Pressure Relief Procedure

Procedure to relieve pressure from pressurized equipment before servicing.

Removing the Existing Air Motor

Steps to remove the existing air motor from the Husky 715 pump.

Installing the New Air Motor

Detailed steps for installing the new air motor components.

Operating the Retrofitted Pump

Reference to manual for operating and service instructions.

Husky 716 Air Motor Retrofit Kit Parts

Parts Identification and List

Lists part numbers, descriptions, and quantities for retrofit kits.

Graco Standard Warranty and Contact

Customer Support and Ordering Information

Contact information for placing orders and identifying the closest distributor.